Link ECU MIPS 150 PSI Pressure Sensor
Link ECU MIPS 150 PSI Pressure Sensor is backordered and will ship as soon as it is back in stock.
Couldn't load pickup availability
OEM References
OEM References
Description
Description
Link MIPS 150 PSI Pressure Sensor
The Link MIPS 150 PSI Pressure Sensor is a media-isolated pressure transducer designed for accurate and reliable pressure measurement in demanding automotive applications.
With a stainless steel body, compact design and 0.5V to 4.5V output, it is suitable for monitoring fuel, oil, coolant and other compatible fluid pressures in motorsport and performance vehicles.
Suitable Applications
Compatible with:
-
All Link ECUs
-
Other aftermarket ECUs with analogue pressure sensor inputs
-
Fuel pressure monitoring
-
Oil pressure monitoring
-
Coolant pressure monitoring
-
Water pressure monitoring
-
Petrol applications
-
Ethanol applications
-
Diesel applications
Key Features
-
Genuine Honeywell MIP Series pressure sensor
-
Pressure range from 0 to 150 PSI
-
1/8"-27 NPT male thread
-
Stainless steel construction
-
Media-isolated sensing element
-
Ratiometric 0.5V to 4.5V analogue output
-
Operating temperature from -40°C to +125°C
-
Compact 22mm hex body
-
Supplied with 3-way Metri-Pack 150 connector kit
Fluid Compatibility
Suitable for use with:
-
Oil
-
Petrol
-
Ethanol
-
Diesel
-
Coolant
-
Water
Pressure Range
0 to 150 PSI
Operating Temperature
-40°C to +125°C
Electrical Specification
Operating Voltage Range: 4.75V to 5.25V
Maximum Input Voltage: 40V
Maximum Continuous Current Draw: 7.5mA
Output Voltage: 0.5V to 4.5V
PCLink Calibration
Select:
1000 kPa (150 PSI) TI Sensor
Raw Calibration
-
0.5V = 0 kPa
-
4.5V = 1034.21 kPa
Thread
1/8"-27 NPT Male
Dimensions
Length: 45mm
Width: 25mm
Height: 25mm
Weight
25g
Connector
-
3-way Metri-Pack 150 connector
What's Included
-
Link MIPS 150 PSI Pressure Sensor
-
3-Way Metri-Pack 150 Connector Kit
-
Printed Accessory Instructions
Please Note
This sensor requires a regulated 5V sensor supply from the ECU.
Use a suitable thread sealant for the fluid being measured and ensure the 150 PSI pressure range is appropriate for the application before installation.
Reviews (0)
Reviews (0)
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.